Interact with this product in a Layout Tool:

The 2408LPS-2 is a standalone dual port LNB power inserter in a high performance and compact platform for inserting DC power via coaxial cable to two LNBs. Can be mounted in the 2400ODU with redundant power supplies.
On the RF input connectors, the module provides +13/+14/+18/+19V DC power and 22kHz tone generation, with low RF insertion loss along with 10MHz injection to LNB.
The 2408LPS-2 also features dynamic or static short circuit current protection; dynamic mode features continuous short circuit check and automatic recovery, while static mode disables DC voltage until a reset is performed. Both modes indicate the short circuit condition on card LEDs, WebGUI and SNMP/VistaLINK® PRO.
For outdoor applications, the 2408LPS-2 is available in a weatherproof (+WP) IP65-rated version, presenting an ideal solution for mounting on or near an antenna structure. The DC power input is via a F-type connector.
The 2408LPS-2 has an Ethernet control port for remote webpage access, along with SNMP support for remote monitoring and control via SNMP or VistaLINK® PRO software, such as LNB current and RF input power monitoring.
Features
- Provide +13/+18V DC voltage with available +1V DC cable compensation for long cable runs
- 10MHz injection and Bias'ed with DC voltage to LNB
- 22kHz tone generation is available on both ports for LNB control
- DC voltage level and 22kHz tone generation are independently controllable at each port
- Dynamic or static short circuit current protection
- RF power and LNB current monitoring with adjustable thresholds when using remote control
- +WP version provides IP65 dust and water protection for mounting outdoors without a supplemental enclosure
- Local monitoring and control is available through comprehensive LED indicators and dial control
Specifications
RF Connector | |
---|---|
Number of Inputs | 2 |
Number of Outputs | 2 |
Connector | BNC per IEC 61169-8 Annex A (F-type and SMA options available) |
I/O Impedance | 50Ω |
RF Performance | |
---|---|
Frequency Response | 240 – 3000MHz ±0.5dB |
Return Loss | 240 – 3000MHz > 9dB |
Isolation | > 60dB |
P1dB | +3dBm |
10MHz Reference Input | |
---|---|
Number of Inputs | 1 |
Input Frequency | 10MHz |
Connector | BNC per IEC 61169-8 Annex A (F-type and SMA options available) |
Impedance | 50Ω |
10MHz Input Power Range | -5 to -60dBm |
Intermod & Harmonics | -72dBm |
LNB Voltage | |
---|---|
Output Voltage | +13/+14/+18/+19V DC (selectable) |
Maximum Output Current | 400mA |
Protection | Short circuit, current limited |
LO Control | 22kHz on/off (selectable) |
Electrical | |
---|---|
Voltage | +18V DC nominal (> 17.5V DC min.) |
Power | 3 watts with no LNB load |
Connector | F-Type |
Conductor Range | 23-18 AWG (0.26-0.82mm2) |
EMI/RFI | Complies with FCC regulations for Class A devices, complies with EU EMC directives |
Environmental | |
---|---|
Operating Temperature | -35 to 55°C |
Dust/Water Protection | IP65 (+WP version) |
Ordering Information
2408LPS-2-B50 | Standalone dual port LNB power inserter, 500mA per port, with 10MHz reference injection, 50Ω BNC connectors, with remote M&C. External power supply ordered separately. |
---|
Ordering Options | |
---|---|
+PS | 18V DC external power supply, 100 – 240V AC auto-ranging input, indoor mounting with F-Type connector. |