The 400FR is designed for those applications requiring high density distribution and processing of balanced analog and digital audio signals.
The 3RU multiframe chassis supports a wide variety of modules within a 3RU footprint. The frame offers dual hot swappable power supplies and provides sixteen slots for 400 series audio modules. Each 400 series processing module is also hot swappable and mates to the rear plane of the 400 frame which is completely passive. The design approach eliminates the need to de-cable the frame in the event of an electronics replacement. Each slot of the 400FR provides ten high-quality 3-pin terminal strip connectors that are used to interface to the processing module.
特点
- Dual hot swappable power supplies with integrated cooling
- Houses up to sixteen 400 series processing modules
- Each processing slot provides individually configurable inputs and outputs
- Monitoring window for verifying module and power supply status
- No recabling required when hot swapping processing modules
指标|
电气 | |
---|---|
AC Mains Input | Auto ranging, 100 to 240V AC, 50/60Hz |
Maximum Operating Current | 2.6A (@ 120V AC), 1.4A (@ 240V AC) |
Maximum Power Consumption | 200 瓦 |
Maximum Module Load | 160 瓦 (10 瓦 per slot) |
Power Supply Configuration | Dual, redundant, separate AC inlets |
端口数目 | IEC 60320 - 1 per power supply |
Fuses | 4A, 250V time delay 5x20 mm. - 2 per power supply |
Safety | CSA Listed to CSA C22.2 No. 60065-03, UL 60065-03 IEC 60065-(2001-12) 7th Edition Complies with CE Low voltage Directive 93/68/EEC |
EMC | Complies with FCC part 15, Class A, Complies with EU EMC directive 89/336/EEC |
物理参数 | |
---|---|
Height | 5.25" (133mm) |
Width | 19" (483mm) |
Depth | 9.5" (368mm) |
Module Capacity | 16 slots |
双通道 | Approx 17lbs (7.7kg) with 2 power supplies, no slots occupied Approx. 32lbs (14.5kg) with 2 power supplies all slots occupied |
Certification | |
---|---|
Safety | CSA Listed, Complies with CE Safety Directive |
EMC | Complies with FCC part 15, Class A, EU EMC Directive |
Operation | |
---|---|
Signal Connections | 3-pin removable terminal strips, balanced connection (10 per slot) |
Status Indicators | PSU status LED, Local Error/Failure LED |
Tally Output Connector | 4-pin terminal, relay N/O, N/C for status/fault alarm 2A, 12.5V DC max |
工作温度 | 0-40°C optimal performance, 0-50°C operating |
订购信息|
400FR | Compact High Density 平衡 Audio Distribution Frame |
---|
订购可选项 | |
---|---|
+4PS | Redundant power supply option for 400FR |
附件 | |
---|---|
400PS | Additional power supply for 400FR |
400FC | 400FR VistaLINK® Frame Controller |